1.4.3 inch color touch screen for clear vision
2.Simple rate mode with one key start,easy to operate
3.Compatible with various brands of syringe
4.Various infusion modes to meet different clinical requirements
5.User friendly interface with audible and visual alarm system
6.Rechargeable lithium battery can work continuously for around 5 hours
1.4.3 inch color touch screen for clear vision
2.Simple rate mode with one key start,easy to operate
3.Compatible with various brands of syringe
4.Various infusion modes to meet different clinical requirements
5.User friendly interface with audible and visual alarm system
6.Rechargeable lithium battery can work continuously for around 5 hours
1.Applicable Syringe: Various brands of sterile syringe: 5ml,0ml, 20ml, 30ml, 50ml/60ml
2.Infusion mode: Rate mode, Rate-time mode, Rate-VIBI
3.Flow rate range: 5ml syringe:0.1-150ml/h;
10ml syringe:0.1-300ml/h;
20ml syringe:0.1-600m/h
30ml syringe:0.1-900m/h
50ml (60ml) syringe:O.1-1500mlh
4.Volume range: 0.1ml-9999ml
5.Flow rate step: 0.1-100ml/h, increment 0.1ml/h
101-1500mlm/h, increment 1m/h
6.Time preset: 1min-99:59 min
7.Accuracy:+2%(After syringe correct calibration)
8.Alarm: Syringe not inserted,No operation,Infusion complete,Battery empty,Occlusion,Battery low, Parameter not confirmed,AC power fail, Syringe Install Error etc.
9.KvO rate: 2.5ml/h
10.Power supply: AC power supply: 100--240V,50/60Hz;
External Dc power supply:7.4V
11.Battery: lnternal rechargeable Lithium battery,1800mAh
12.Battery working time: Around 5 hours
13.Screen: 4.3"L CD touch screen
14.Dimension: 220*180*80mm
15.Operation environment: Temperature +10~+30°℃
Relative Humidity S70%
Atmospheric Pressure 86 KPa~106KPa
16.Storage environment: Temperature:-10~+55°℃
Humidity: <80%
1.Applicable Syringe: Various brands of sterile syringe: 5ml,0ml, 20ml, 30ml, 50ml/60ml
2.Infusion mode: Rate mode, Rate-time mode, Rate-VIBI
3.Flow rate range: 5ml syringe:0.1-150ml/h;
10ml syringe:0.1-300ml/h;
20ml syringe:0.1-600m/h
30ml syringe:0.1-900m/h
50ml (60ml) syringe:O.1-1500mlh
4.Volume range: 0.1ml-9999ml
5.Flow rate step: 0.1-100ml/h, increment 0.1ml/h
101-1500mlm/h, increment 1m/h
6.Time preset: 1min-99:59 min
7.Accuracy:+2%(After syringe correct calibration)
8.Alarm: Syringe not inserted,No operation,Infusion complete,Battery empty,Occlusion,Battery low, Parameter not confirmed,AC power fail, Syringe Install Error etc.
9.KvO rate: 2.5ml/h
10.Power supply: AC power supply: 100--240V,50/60Hz;
External Dc power supply:7.4V
11.Battery: lnternal rechargeable Lithium battery,1800mAh
12.Battery working time: Around 5 hours
13.Screen: 4.3"L CD touch screen
14.Dimension: 220*180*80mm
15.Operation environment: Temperature +10~+30°℃
Relative Humidity S70%
Atmospheric Pressure 86 KPa~106KPa
16.Storage environment: Temperature:-10~+55°℃
Humidity: <80%