1.Windows operation interface, figure button, mouse operation, touch screen.
2.96-well plate, multiple tests in the single plate.
3.Arrangement of Test item in micro-plate can be store and re-use
4.Parameter can be modified and stored
5.Plate shaking, speed and time adjustable
6.Open system, test item and parameters can be added or modified.
7.Large storage for 1000 test item and 1,000,000 results
8.10.4 inch color touch LCD
9.Printing comprehensive report, include hospital and patient information and test results
10.Built-in portable computer, easy to use.
1.Windows operation interface, figure button, mouse operation, touch screen.
2.96-well plate, multiple tests in the single plate.
3.Arrangement of Test item in micro-plate can be store and re-use
4.Parameter can be modified and stored
5.Plate shaking, speed and time adjustable
6.Open system, test item and parameters can be added or modified.
7.Large storage for 1000 test item and 1,000,000 results
8.10.4 inch color touch LCD
9.Printing comprehensive report, include hospital and patient information and test results
10.Built-in portable computer, easy to use.
1.Microplate types: 96-well plate(U,V,or plat-bottom)
2.Wavelength: 405nm, 450nm, 492nm, 630nm, wavelength accuracy < 2nm
3.Reading range: 0.000-4.000 Abs
4.Measurement range: 0.000-3.000Abs
5.Light source: LED, >100,000 hours
6.Measuring system: 8-channel optical system
7.Test mode: End-point, kinetic, Multi-wave analysis
8.Resolution <1% or士0.001Abs
9.Stability: <士0.005Abs/10min
10.Well Coincidence:≤0.015A
11.Linearity:r> 0.999
12.Repeatability: < 0.3%
13.Reading speed: 5s single wavelength , 10s double wavelength
14.QC: West guard Multi-rule, automated QC alert.
15.Self-Checking function: Self-checking and calibration function.
16.CPU: High-speed CPU
17 Printer: External jet printer, multi -form patient report.
18.Interface: RS232 interface, USB.
19.Power supply: 220VAC 15% or 110VAC 15%50-60Hz 100
20.Work environment: Temp 5°C- 40°C; Humi≤85%;
21.Machine Dimension: 44CM*37CM*24CM
22.Weight: 13 KG
1.Microplate types: 96-well plate(U,V,or plat-bottom)
2.Wavelength: 405nm, 450nm, 492nm, 630nm, wavelength accuracy < 2nm
3.Reading range: 0.000-4.000 Abs
4.Measurement range: 0.000-3.000Abs
5.Light source: LED, >100,000 hours
6.Measuring system: 8-channel optical system
7.Test mode: End-point, kinetic, Multi-wave analysis
8.Resolution <1% or士0.001Abs
9.Stability: <士0.005Abs/10min
10.Well Coincidence:≤0.015A
11.Linearity:r> 0.999
12.Repeatability: < 0.3%
13.Reading speed: 5s single wavelength , 10s double wavelength
14.QC: West guard Multi-rule, automated QC alert.
15.Self-Checking function: Self-checking and calibration function.
16.CPU: High-speed CPU
17 Printer: External jet printer, multi -form patient report.
18.Interface: RS232 interface, USB.
19.Power supply: 220VAC 15% or 110VAC 15%50-60Hz 100
20.Work environment: Temp 5°C- 40°C; Humi≤85%;
21.Machine Dimension: 44CM*37CM*24CM
22.Weight: 13 KG