Biochemistry Analyzer is designed for hospital or clinical laboratory to masure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.e
Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber, condensate cooling design and peltier cooling system double ensure the cooling effect.
Powerful reaction cuvette washing system
ISE Unit &barcode scanner (optional)
Lower waste and pro-environment
Model | LB-261 | |
Analytical System | Fully automatic, Random Access, Discrete | |
Method | End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc | |
Assay Item | 40 assay | |
ISE mould(K+, Na+, Cl-, Ca2+) available on request | ||
Throughput | 1 Reagent | 240 tests/hr |
2 Reagent | 150 tests/hr | |
With ISE | 120 tests/hr | |
Test Menu | T.BILI r-GT/GGT CHO Ca APOB-1/B CHE | |
D.BILI ALP/AKP TG CL APOB CREA | ||
TP UREA CK P CK-MB Mg | ||
ALB CREA LDH C ASO AFU | ||
Lactic Acid ALT/GPT UA α-HBDH CO2 FMN | ||
LP(a) AST/GOT GLU AMY LDL-C HDL-C | ||
CHE LA TBA ADA HS-CRP PA | ||
Fe Cu Zn C3 C4 IgG | ||
IgM IgA and drug, toxicity,etc. | ||
Sample Position | 60 | |
Including standard, control and STAT; either serum cup or primary tube available | ||
Sample Volume | 1~100ul, 0.1ul/step | |
Reagent Position | 40 | |
Reagent Volume | R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step | |
Reagent/Sample Probe | With liquid level sensor, collision sensor, Teflon coating and automatic washing station | |
Reaction Time | 0~999 seconds | |
Cuvette | High quality uv-transmitted plastic cuvette. | |
Cuvette Washing | 8 channels automatic washing system for reaction cuvettes | |
Probe and Mixer Washing | Independent washing station for each sample/reagent probe and mixer | |
Alarm | Automatic alarm for malfunction (eg:collision, reagent/sample insufficiency, full waste container, etc) | |
Calibration | Linear, Non-linear, Multi standard, K factor | |
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function | |
Wavelength | 340-810nm | |
Light Source | Halogen lamp | |
Absorbance Resolution | 0.0001A | |
AbsorbanceAccuracy | ±0.0003A(0-2.5A) | |
Repeatability | ±2% | |
Quality Control | Levy jennings quality control program at 3 levels | |
Barcode | Optional | |
Printer | Multiple report formats available | |
System | Windows XP; Windows 7 | |
Power Supply | 220V or 110V, 50~60Hz | |
Dimension | 85×72×53(cm) | |
Weight | 85kg |
5.Water consumption: 6L/h
Lab Equipment Full Automatic Biochemical Analyzer Clinical Analytical Instruments Chemistry Analyzer
Model:LB-261
Product Description
Biochemistry Analyzer is designed for hospital or clinical laboratory to masure the quantity of chemical or biochemical components in human serum, urine and other liquid sample, used to test liver function, kidney function, cardiac markers, blood sugar, blood lipid, etc.e
Features:
Random access fully automatic biochemistry analyzer
New concept and more friendly software
Automatic washing station for both sample and reagent probe
Liquid level detection and collision protection for both sample and reagent probe
Reliable cooling system for reagent chamber, condensate cooling design and peltier cooling system double ensure the cooling effect.
Powerful reaction cuvette washing system
ISE Unit &barcode scanner (optional)
Lower waste and pro-environment
Model | LB-261 | |
Analytical System | Fully automatic, Random Access, Discrete | |
Method | End point, Rate, Fixed time, Immunoturbidimetric, 1-2 regent, Multistandard, reagent/serum blank, etc | |
Assay Item | 40 assay | |
ISE mould(K+, Na+, Cl-, Ca2+) available on request | ||
Throughput | 1 Reagent | 240 tests/hr |
2 Reagent | 150 tests/hr | |
With ISE | 120 tests/hr | |
Test Menu | T.BILI r-GT/GGT CHO Ca APOB-1/B CHE | |
D.BILI ALP/AKP TG CL APOB CREA | ||
TP UREA CK P CK-MB Mg | ||
ALB CREA LDH C ASO AFU | ||
Lactic Acid ALT/GPT UA α-HBDH CO2 FMN | ||
LP(a) AST/GOT GLU AMY LDL-C HDL-C | ||
CHE LA TBA ADA HS-CRP PA | ||
Fe Cu Zn C3 C4 IgG | ||
IgM IgA and drug, toxicity,etc. | ||
Sample Position | 60 | |
Including standard, control and STAT; either serum cup or primary tube available | ||
Sample Volume | 1~100ul, 0.1ul/step | |
Reagent Position | 40 | |
Reagent Volume | R1: 1~400ul, 0.1ul/step, R2: 1~400ul, 0.1ul/step | |
Reagent/Sample Probe | With liquid level sensor, collision sensor, Teflon coating and automatic washing station | |
Reaction Time | 0~999 seconds | |
Cuvette | High quality uv-transmitted plastic cuvette. | |
Cuvette Washing | 8 channels automatic washing system for reaction cuvettes | |
Probe and Mixer Washing | Independent washing station for each sample/reagent probe and mixer | |
Alarm | Automatic alarm for malfunction (eg:collision, reagent/sample insufficiency, full waste container, etc) | |
Calibration | Linear, Non-linear, Multi standard, K factor | |
Sample Dilution/Retest | Sample can be diluted and retested if results are out of range or sample is insufficient. Also with calibrator auto diluting function | |
Wavelength | 340-810nm | |
Light Source | Halogen lamp | |
Absorbance Resolution | 0.0001A | |
AbsorbanceAccuracy | ±0.0003A(0-2.5A) | |
Repeatability | ±2% | |
Quality Control | Levy jennings quality control program at 3 levels | |
Barcode | Optional | |
Printer | Multiple report formats available | |
System | Windows XP; Windows 7 | |
Power Supply | 220V or 110V, 50~60Hz | |
Dimension | 85×72×53(cm) | |
Weight | 85kg |
5.Water consumption: 6L/h