1. Unique dual radio frequency design. Combine 4Mhz and 1.7Mhzinto one generator.Realize the best operation result effectively.Suitable for Plastic, Dermatology, ENT, Ophthalmology,Dentistry ,Podiatry and Spinal surgery etc..
2. Clinic result proves that higher frequency can get less tissueresistance.4Mhz frequency can reduces heat injury and
carbonizing to tissue at maximum. It realizes low temperaturecutting.
3. Antenna pad is unnecessary for skin touch, no current goesthrough body and no possibility of burning
4. No pressure cutting and the pencil is operated easily and it'sfull of flexibility.
5. No carbonation, less bleeding and no adhesions.
6. Less pain , scarring and fast-healing after operation.
1. Unique dual radio frequency design. Combine 4Mhz and 1.7Mhzinto one generator.Realize the best operation result effectively.Suitable for Plastic, Dermatology, ENT, Ophthalmology,Dentistry ,Podiatry and Spinal surgery etc..
2. Clinic result proves that higher frequency can get less tissueresistance.4Mhz frequency can reduces heat injury and
carbonizing to tissue at maximum. It realizes low temperaturecutting.
3. Antenna pad is unnecessary for skin touch, no current goesthrough body and no possibility of burning
4. No pressure cutting and the pencil is operated easily and it'sfull of flexibility.
5. No carbonation, less bleeding and no adhesions.
6. Less pain , scarring and fast-healing after operation.
Mode/Character | Output Waveform | Nominal Output Power |
CUT | 4.0 MHz sinusoid | 120W@500Ω |
CUT/COAG | 4.0 MHz with fully rectified envelope | 80W@500Ω |
HEMO | 4.0 MHz with fully rectified envelope | 60W@500Ω |
FULGURATE | 4.0 MHz with modulation | 40W@500Ω |
BIPOLAR | 1.7MHz | 120W@200Ω |
1. Operating Ambient Temperature:-40℃~55℃
2. Relative humidity range:≤80%
3. Atmospheric Pressure range:50kPa~106kPa
4. Power Supply:120/230V~, 60/50Hz
5. lnput current at max output power:2/4A
Output Mode
CUT - For micro-smooth cutting
BLEND - For cutting with coagulation
HEMO - For pure Hemostasis-Coagulation to control most forms of bleedingFULGURATION - For desiccation or fulgurate spark-gap
BIPOLAR - For precise coagulation utilizing bipolar energy
Intended Use
Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP),myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses,tumors, cosmetic repairs,development of skin flaps, skin tags and blepharoplasty.
Blended (cutting and coagulation): snoring,submucosal palatal shrinkage, traditional .uvulopalatoplasty(RAUP), myringotomy with effective hemorrhage control, epistaxistreatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae,basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses,and development of skin flaps.
Hemostasis: control of bleeding, epilation, telangiectasia.
Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae,hemostasis.
Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry),snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP),myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
Mode/Character | Output Waveform | Nominal Output Power |
CUT | 4.0 MHz sinusoid | 120W@500Ω |
CUT/COAG | 4.0 MHz with fully rectified envelope | 80W@500Ω |
HEMO | 4.0 MHz with fully rectified envelope | 60W@500Ω |
FULGURATE | 4.0 MHz with modulation | 40W@500Ω |
BIPOLAR | 1.7MHz | 120W@200Ω |
1. Operating Ambient Temperature:-40℃~55℃
2. Relative humidity range:≤80%
3. Atmospheric Pressure range:50kPa~106kPa
4. Power Supply:120/230V~, 60/50Hz
5. lnput current at max output power:2/4A
Output Mode
CUT - For micro-smooth cutting
BLEND - For cutting with coagulation
HEMO - For pure Hemostasis-Coagulation to control most forms of bleedingFULGURATION - For desiccation or fulgurate spark-gap
BIPOLAR - For precise coagulation utilizing bipolar energy
Intended Use
Cutting: snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP),myringotomy with effective hemorrhage control, epistaxis treatment, turbinate shrinkage, skin incisions, biopsy, cysts, abscesses,tumors, cosmetic repairs,development of skin flaps, skin tags and blepharoplasty.
Blended (cutting and coagulation): snoring,submucosal palatal shrinkage, traditional .uvulopalatoplasty(RAUP), myringotomy with effective hemorrhage control, epistaxistreatment, turbinate shrinkage, skin tags, papilloma keloids, keratosis, verrucae,basal cell carcinoma, nevi, fistulas, epithelioma, cosmetic repairs, cysts, abscesses,and development of skin flaps.
Hemostasis: control of bleeding, epilation, telangiectasia.
Fulguration: basal cell carcinoma, papilloma, cyst destruction, tumors, verrucae,hemostasis.
Bipolar: pinpoint precise coagulation, pinpoint hemostasis in any field (wet or dry),snoring, submucosal palatal shrinkage, traditional uvulopalatoplasty (RAUP),myringotomy with effective hemorrhage control, epistaxis treatment and turbinate shrinkage.
1. lnstruction for Use: 1pc
2. Power Cord:1pc
3. Dual Pedal Switch: 1pc
4. Disposable ESU Pencil: 2 pcs
5. Reusable Antenna Pad with cable : 1 set
6. Reusable Bipolar Forceps with Cable: 1 set
7. Reusable ESU pencil: 1 pc
8. Reusable Fine Electrode tips (Needle, curved, Needle ,Ball): 7pcs
9. Disposable leep Electrode tips: 5pcs
1. lnstruction for Use: 1pc
2. Power Cord:1pc
3. Dual Pedal Switch: 1pc
4. Disposable ESU Pencil: 2 pcs
5. Reusable Antenna Pad with cable : 1 set
6. Reusable Bipolar Forceps with Cable: 1 set
7. Reusable ESU pencil: 1 pc
8. Reusable Fine Electrode tips (Needle, curved, Needle ,Ball): 7pcs
9. Disposable leep Electrode tips: 5pcs
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634