1.7 inch high resolution color touch screen.
2.12-lead simultaneous acquisition and display. .
3.ECG Automatic measurement and interpretation function.
4.Complete digital filters, resisting baseline drift, AC and EMG interference.
5.Compact and lightweight design.
6.Support USB flash disk and micro SD card to extend memory.
7.Software upgrade via USB/SD card.
8.Built-in rechargeable Li-ion battery.
1.7 inch high resolution color touch screen.
2.12-lead simultaneous acquisition and display. .
3.ECG Automatic measurement and interpretation function.
4.Complete digital filters, resisting baseline drift, AC and EMG interference.
5.Compact and lightweight design.
6.Support USB flash disk and micro SD card to extend memory.
7.Software upgrade via USB/SD card.
8.Built-in rechargeable Li-ion battery.
1.Lead Standard: 12 leads
2.Acquisition Mode: Simultaneous 12 leads acquisition
3.Measurement Range:土5mVpp
4.Input circuit: Floating; Protection circuit against Defibrillator effect
5.Input Impedance:≥50M
6.Input circuit current: <0.05μA
7.Record mode: Automatic:3CHx4+1R,3CHx4,3CHx2+2CHx3,3CHx2+2CHx3+1 R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
8.Filter: EMG Filter:25 Hz / 30 Hz/ 40Hz/75 Hz / 100HZ/ 150Hz
DFT Filter: 0.05 Hz/0.15 Hz
Filter:50 Hz / 60Hz
9.CMRR: >100dB
10.Patient leak current: < 10μA (220V-240V)
11.Frequency Response: 0.05Hz- 150Hz (-3dB)
12.Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error:土5%)
13.Anti-baseline Drift: Automatic
14.Time constant:≥3.2s
15.Noise level: < 15μV p-p
16.Paper speed: 12.5mm/s, 25mm/s, 50mm/s
17.Recording mode: Thermal printing system
18.Paper specification: Roll 80mmx20M
19. Safety Standard: IEC I/CF
20.Sample Rate Normal: 1000sps/channel
21.Power Supply: AC: 100-240V, 50/60Hz, 30VA- 100VA
DC: 14.8V/2200mAh, built-in lithium battery
1.Lead Standard: 12 leads
2.Acquisition Mode: Simultaneous 12 leads acquisition
3.Measurement Range:土5mVpp
4.Input circuit: Floating; Protection circuit against Defibrillator effect
5.Input Impedance:≥50M
6.Input circuit current: <0.05μA
7.Record mode: Automatic:3CHx4+1R,3CHx4,3CHx2+2CHx3,3CHx2+2CHx3+1 R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
8.Filter: EMG Filter:25 Hz / 30 Hz/ 40Hz/75 Hz / 100HZ/ 150Hz
DFT Filter: 0.05 Hz/0.15 Hz
Filter:50 Hz / 60Hz
9.CMRR: >100dB
10.Patient leak current: < 10μA (220V-240V)
11.Frequency Response: 0.05Hz- 150Hz (-3dB)
12.Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error:土5%)
13.Anti-baseline Drift: Automatic
14.Time constant:≥3.2s
15.Noise level: < 15μV p-p
16.Paper speed: 12.5mm/s, 25mm/s, 50mm/s
17.Recording mode: Thermal printing system
18.Paper specification: Roll 80mmx20M
19. Safety Standard: IEC I/CF
20.Sample Rate Normal: 1000sps/channel
21.Power Supply: AC: 100-240V, 50/60Hz, 30VA- 100VA
DC: 14.8V/2200mAh, built-in lithium battery
Main machine: 1 PC.
Patient cable:1 PC.
Limb electrode: 1 set (4pcs).
Chest electrode: 1 set( 6pcs). .
Power cable: 1 PC.
Recording paper: 1 PC(110mm*20m).
Paper axis: 1 PC.
Power cord: 1 PC.
Main machine: 1 PC.
Patient cable:1 PC.
Limb electrode: 1 set (4pcs).
Chest electrode: 1 set( 6pcs). .
Power cable: 1 PC.
Recording paper: 1 PC(110mm*20m).
Paper axis: 1 PC.
Power cord: 1 PC.