1.7 inch high resolution color touch screen.
2.12-lead simultaneous acquisition and display.
3.ECG Automatic measurement and interpretation function.
4.Complete digital filters, resisting baseline drift, AC and EMG interference .
5.Compact and lightweight design.
6.Support USB flash disk and micro SD card to extend memory.
7.Software upgrade via USB/SD card.
8.Built-in rechargeable Li-ion battery.
1.7 inch high resolution color touch screen.
2.12-lead simultaneous acquisition and display.
3.ECG Automatic measurement and interpretation function.
4.Complete digital filters, resisting baseline drift, AC and EMG interference .
5.Compact and lightweight design.
6.Support USB flash disk and micro SD card to extend memory.
7.Software upgrade via USB/SD card.
8.Built-in rechargeable Li-ion battery.
1.Lead Standard: 12 leads
2.Acquisition Mode: Simultaneous 12 leads acquisition
3.Measurement Range:土5mVpp
4.Input circuit: Floating; Protection circuit against Defibrillator effect
5.Input Impedance:≥50M
6.Input circuit current: <0.05μA
7.Record mode: Automatic:3CHx4+1R,3CHx4,3CHx2+2CHx3,3CHx2+2CHx3+1 R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
8.Filter: EMG Filter:25 Hz / 30 Hz/ 40Hz/75 Hz / 100HZ/ 150Hz
DFT Filter: 0.05 Hz/0.15 Hz
Filter:50 Hz / 60Hz
9.CMRR: >100dB
10.Patient leak current: < 10μA (220V-240V)
11.Frequency Response: 0.05Hz- 150Hz (-3dB)
12.Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error:土5%)
13.Anti-baseline Drift: Automatic
14.Time constant:≥3.2s
15.Noise level: < 15μV p-p
16.Paper speed: 12.5mm/s, 25mm/s, 50mm/s
17.Recording mode: Thermal printing system
18.Paper specification: Roll 80mmx20M
19.Safety Standard: IEC I/CF
20.Sample Rate Normal: 1000sps/channel
21.Power Supply: AC: 100-240V, 50/60Hz, 30VA-100VA
DC: 14.8V/2200mAh, built-in lithium battery
1.Lead Standard: 12 leads
2.Acquisition Mode: Simultaneous 12 leads acquisition
3.Measurement Range:土5mVpp
4.Input circuit: Floating; Protection circuit against Defibrillator effect
5.Input Impedance:≥50M
6.Input circuit current: <0.05μA
7.Record mode: Automatic:3CHx4+1R,3CHx4,3CHx2+2CHx3,3CHx2+2CHx3+1 R,6CHX2;
Manual: 3CH, 2CH, 3CH+1R, 2CH+1R;
Rhythm: Any lead selectable.
8.Filter: EMG Filter:25 Hz / 30 Hz/ 40Hz/75 Hz / 100HZ/ 150Hz
DFT Filter: 0.05 Hz/0.15 Hz
Filter:50 Hz / 60Hz
9.CMRR: >100dB
10.Patient leak current: < 10μA (220V-240V)
11.Frequency Response: 0.05Hz- 150Hz (-3dB)
12.Sensitivity: 2.5mm/mV, 5 mm/mV, 10 mm/mV, 20 mm/mV (error:土5%)
13.Anti-baseline Drift: Automatic
14.Time constant:≥3.2s
15.Noise level: < 15μV p-p
16.Paper speed: 12.5mm/s, 25mm/s, 50mm/s
17.Recording mode: Thermal printing system
18.Paper specification: Roll 80mmx20M
19.Safety Standard: IEC I/CF
20.Sample Rate Normal: 1000sps/channel
21.Power Supply: AC: 100-240V, 50/60Hz, 30VA-100VA
DC: 14.8V/2200mAh, built-in lithium battery
Main machine: 1 PC.
Patient cable:1 PC.
Limb electrode: 1 set (4pcs).
Chest electrode: 1 set( 6pcs). .
Power cable: 1 PC.
Recording paper: 1 PC(80mm*20m).
Paper axis: 1 PC.
Power cord: 1 PC.
Main machine: 1 PC.
Patient cable:1 PC.
Limb electrode: 1 set (4pcs).
Chest electrode: 1 set( 6pcs). .
Power cable: 1 PC.
Recording paper: 1 PC(80mm*20m).
Paper axis: 1 PC.
Power cord: 1 PC.
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634