Battery Level lndicator
To monitor the battery real time
Biphasic Technology
With impedance compensation More effective.
Less Energy and less hurt to the heart
Internal 1 Thermal Printer
50mm integrated thermal recorder
Data Storage
65 hours of all measured parameters
Paddle
Charging and shocking can be easily operated through according buttons
Battery Level lndicator
To monitor the battery real time
Biphasic Technology
With impedance compensation More effective.
Less Energy and less hurt to the heart
Internal 1 Thermal Printer
50mm integrated thermal recorder
Data Storage
65 hours of all measured parameters
Paddle
Charging and shocking can be easily operated through according buttons
Display
Display Type: 8 inch high resolution LCD displaysweep Speed: 25mm/sec
Information: HR, Lead/Pads,On/Off Alarm,Sp02,AEDFunctions and Prompts,Alarm Se-
lection and Limits, Delivered Energy.
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode lmpedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 5 -lead ECG cable, or 3-lead ECG cable,paddles.
Lead Selection: Displayed on monitor, paddles,l, ll,II1, AVR,AVL,AVF,V.
ECG Size:0.25,0.5,1,1.5,2,4 cm/mv diplay on monitor.Heart Rate: 20- -300BPM.
Heart Rate Alarm: On/Off displayed on monitor,user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockablerhythm.
Recorder
Paper: 50mm thermal.
Speed:12.5mm/sec, 25mm/sec,50mm/sec. User- selectable 6--second delay.
Printing Method:High-resolution, thermal print head.
Print-out Modes:Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrllator chargeor defibillator discharge.
Battery
Type: Rechargeable,Ni-MH battery,12V.
Operating Time:For a new, fully charged battery: 60 defirillator discharges at maximumenergy, or 3 hours minimum of continuous ECG monitoring.
Additional parameters will effect operating time with different functions.AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection,screen prompts, and voice prompts.
Shockable Rhythms: Ventricular firillation with amplitude >=200Uv, ventricular tachycardiawith rates >=140bpm,
and QRS complex wave duration >=1 40ms.
Charge Control: Control on device front panel, press key on paddle.Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at2,5,7,10,20,30,50,70,100,150,200,300,360 joules.
Synchronized Mode: Synchronizes defibillator pulse to patient's R-wave. "SYNC" messagedisplayed on monitor
Optional
MB _pacer
MB_EtCO2
MB_NIBP
SPO2 Moudle
Display
Display Type: 8 inch high resolution LCD displaysweep Speed: 25mm/sec
Information: HR, Lead/Pads,On/Off Alarm,Sp02,AEDFunctions and Prompts,Alarm Se-
lection and Limits, Delivered Energy.
Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new fully charged battery.
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode lmpedance Measurement Range: 0-250 ohms.
ECG Monitoring
Patient Connection: 5 -lead ECG cable, or 3-lead ECG cable,paddles.
Lead Selection: Displayed on monitor, paddles,l, ll,II1, AVR,AVL,AVF,V.
ECG Size:0.25,0.5,1,1.5,2,4 cm/mv diplay on monitor.Heart Rate: 20- -300BPM.
Heart Rate Alarm: On/Off displayed on monitor,user-selectable.
Smart Alarms: Beeper/voice prompts indicate shockablerhythm.
Recorder
Paper: 50mm thermal.
Speed:12.5mm/sec, 25mm/sec,50mm/sec. User- selectable 6--second delay.
Printing Method:High-resolution, thermal print head.
Print-out Modes:Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation or defibrllator chargeor defibillator discharge.
Battery
Type: Rechargeable,Ni-MH battery,12V.
Operating Time:For a new, fully charged battery: 60 defirillator discharges at maximumenergy, or 3 hours minimum of continuous ECG monitoring.
Additional parameters will effect operating time with different functions.AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection,screen prompts, and voice prompts.
Shockable Rhythms: Ventricular firillation with amplitude >=200Uv, ventricular tachycardiawith rates >=140bpm,
and QRS complex wave duration >=1 40ms.
Charge Control: Control on device front panel, press key on paddle.Prompts: Voice and visual prompts.
Manual Mode
Energy Selection: Selectable at2,5,7,10,20,30,50,70,100,150,200,300,360 joules.
Synchronized Mode: Synchronizes defibillator pulse to patient's R-wave. "SYNC" messagedisplayed on monitor
Optional
MB _pacer
MB_EtCO2
MB_NIBP
SPO2 Moudle