1. ESU with Ultrahigh Frequency 3.8MHz reducesthe thermal diffusion of the cutting at the greatlylimits, with precisecutting, the less thermal damageand no side tissue is burned.
2. Equipped with Antenna pad, and touch the skin isconsidered as unnecessary and none of the current
goes through the body and no possibility of burning and high security.
3. No pressure cutting and and the pencil is operated easily and it's full offlexibility.
4. No carbonation, less bleeding and no adhesions.
5. The pain is reduced, less scarring and fast-healing after the operation.
1. ESU with Ultrahigh Frequency 3.8MHz reducesthe thermal diffusion of the cutting at the greatlylimits, with precisecutting, the less thermal damageand no side tissue is burned.
2. Equipped with Antenna pad, and touch the skin isconsidered as unnecessary and none of the current
goes through the body and no possibility of burning and high security.
3. No pressure cutting and and the pencil is operated easily and it's full offlexibility.
4. No carbonation, less bleeding and no adhesions.
5. The pain is reduced, less scarring and fast-healing after the operation.
1. Operating ambient temperature: 10°℃ ~40°c
2. Relative humidity range: <80%
3. Pressure range: 50.0kPa~106.0kPa
4. Power Supply: 220/11oV,50/60Hz
5. Operation Frequency: 3.8MHz
Output Mode
First Option/Pure Cut: Applicable to micro and precise cutting, for instance,the head, the neck and thesensitive part as well.Minimal lateral thermaldamage, and it's good for cosmetic effect and wound healing.lt's used forthe biopsy collection and the flap transplantation
Second Option/Blend Cut: Coagulation is activated during cutting, and it'sapplicable to cutting and peel-off of the subcutaneous tissue, particularlyfor the section full of blood.
Third Option/Pure Coagulation: It's applicable to the coagulation and thetissue contraction.lt is usedat the cutting, which needs the excellenthemostatic.
Fulguration: The max tissue injury and hemostasis could be achieved.It'sapplicable to the destruction of the internal tissue.
Bipolar: Good for the accurate pinpoint coagulation
1. Operating ambient temperature: 10°℃ ~40°c
2. Relative humidity range: <80%
3. Pressure range: 50.0kPa~106.0kPa
4. Power Supply: 220/11oV,50/60Hz
5. Operation Frequency: 3.8MHz
Output Mode
First Option/Pure Cut: Applicable to micro and precise cutting, for instance,the head, the neck and thesensitive part as well.Minimal lateral thermaldamage, and it's good for cosmetic effect and wound healing.lt's used forthe biopsy collection and the flap transplantation
Second Option/Blend Cut: Coagulation is activated during cutting, and it'sapplicable to cutting and peel-off of the subcutaneous tissue, particularlyfor the section full of blood.
Third Option/Pure Coagulation: It's applicable to the coagulation and thetissue contraction.lt is usedat the cutting, which needs the excellenthemostatic.
Fulguration: The max tissue injury and hemostasis could be achieved.It'sapplicable to the destruction of the internal tissue.
Bipolar: Good for the accurate pinpoint coagulation
1. lnstruction for Use: 1pc
2. Power Cord:1pc
3. Dual Pedal Switch: 1pc
4. Disposable ESU Pencil: 2 pcs
5. Reusable Antenna Pad with cable : 1 set
6. Reusable Bipolar Forceps with Cable: 1 set
7. Reusable Fine Electrode tips (Needle, curved, Needle ,Ball): 7pcs
8. Disposable leep Electrode tips: 5pcs
1. lnstruction for Use: 1pc
2. Power Cord:1pc
3. Dual Pedal Switch: 1pc
4. Disposable ESU Pencil: 2 pcs
5. Reusable Antenna Pad with cable : 1 set
6. Reusable Bipolar Forceps with Cable: 1 set
7. Reusable Fine Electrode tips (Needle, curved, Needle ,Ball): 7pcs
8. Disposable leep Electrode tips: 5pcs
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA