1. 10.2" touch-screen and intuitive user interface enables clinicians to easily operate and monitor.
2. VCV, PCV,PSV(BACKUP),SIMV-VC,SIMv-PC,MAN./SPONT,PRVC,SIMV-PRVC(optional)
3. General purpose device for all patient groups, from neonates to adults.The minimum setting tidal volume down to 10 ml (optional).
4. The ventilator can automatically set ventila- tion parameters and alarms based on the lBwcalculated from the patient height input,so less time is spent maneuvering and more time isdevoted to patient care.
5. Automatic fresh gas compensation maintain accurate tidal volumes with a wide range offresh gas flows.
6. More than 90 min continuous operating time with large capacity Lithium battery.
7. Auxilliary Common Gas Outlet(ACGo)
8. Selectable five waveforms and three loops display,waveforms and loops display is easyswitch.
9. Electronic PEEP-accurate and convenient
10. Integrated pulse oximetry and sidestream capnography (optional)
11. Three drawers (optional)
1. 10.2" touch-screen and intuitive user interface enables clinicians to easily operate and monitor.
2. VCV, PCV,PSV(BACKUP),SIMV-VC,SIMv-PC,MAN./SPONT,PRVC,SIMV-PRVC(optional)
3. General purpose device for all patient groups, from neonates to adults.The minimum setting tidal volume down to 10 ml (optional).
4. The ventilator can automatically set ventila- tion parameters and alarms based on the lBwcalculated from the patient height input,so less time is spent maneuvering and more time isdevoted to patient care.
5. Automatic fresh gas compensation maintain accurate tidal volumes with a wide range offresh gas flows.
6. More than 90 min continuous operating time with large capacity Lithium battery.
7. Auxilliary Common Gas Outlet(ACGo)
8. Selectable five waveforms and three loops display,waveforms and loops display is easyswitch.
9. Electronic PEEP-accurate and convenient
10. Integrated pulse oximetry and sidestream capnography (optional)
11. Three drawers (optional)
Mode of Ventilation
VCV,PCV,SIMV-vCV,SIMv-PCVPS with Backup mode(VCV or PCV)
Manual/Spontneous with respiratory monitoring
PRVC,SIMV-PRVC(optional)
Ventilation Settings
Tidal Volume:50~1500ml;10~50ml (optional)
Frequency:1~100bpm
Tinsp:0.1~10.0s
l:E:4:1~1:10
Pause:0~50%
PEEP:OFF,3~20
Pressure Support:0~80cmH2O
Pressure Control:5~80cmH2O
Fsens:0.5~20L/min
Psens:0~20cmH-O
Tslope:0~2s
Esens:5-80%
Mode of Ventilation
VCV,PCV,SIMV-vCV,SIMv-PCVPS with Backup mode(VCV or PCV)
Manual/Spontneous with respiratory monitoring
PRVC,SIMV-PRVC(optional)
Ventilation Settings
Tidal Volume:50~1500ml;10~50ml (optional)
Frequency:1~100bpm
Tinsp:0.1~10.0s
l:E:4:1~1:10
Pause:0~50%
PEEP:OFF,3~20
Pressure Support:0~80cmH2O
Pressure Control:5~80cmH2O
Fsens:0.5~20L/min
Psens:0~20cmH-O
Tslope:0~2s
Esens:5-80%
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634