1. More convenient operating and display systems for clinical operations; Suitable fora wide range of anesthesia: adult and pediatric.(Tidal volume Optional 20~1500ml)
2. Electronic PEEP,Imported proportional valve, traditional 6 tubes flowmeter, allensure the excellent performance,durable, long-term use.
3. Highly integrated circuits,the overall heat auto circuit technology to avoidcondensation circuit; by-pass bypass function,the canister can be replaced in thecourse of anesthesia, no harmful gas leakage.
4. Sufficient monitoring parameter: Ppeak,Pmean,Pmin,Pplat,PEEP Compliance,Resistance,O2%, EtCO2,FiCO2.
5. Clinician's health concerns: Independent AGSS exhaust vent and active sewagesystems avoid anesthesia gas pollution.
6.Complete alarm function to make sure the operation accuracy and stability.
1. More convenient operating and display systems for clinical operations; Suitable fora wide range of anesthesia: adult and pediatric.(Tidal volume Optional 20~1500ml)
2. Electronic PEEP,Imported proportional valve, traditional 6 tubes flowmeter, allensure the excellent performance,durable, long-term use.
3. Highly integrated circuits,the overall heat auto circuit technology to avoidcondensation circuit; by-pass bypass function,the canister can be replaced in thecourse of anesthesia, no harmful gas leakage.
4. Sufficient monitoring parameter: Ppeak,Pmean,Pmin,Pplat,PEEP Compliance,Resistance,O2%, EtCO2,FiCO2.
5. Clinician's health concerns: Independent AGSS exhaust vent and active sewagesystems avoid anesthesia gas pollution.
6.Complete alarm function to make sure the operation accuracy and stability.
System Specifications | |
Technical Parameters | Specification |
Machine | |
Size | 1410x950x650(HxWxD) |
Weight | 110kg |
Top cover | 30kg bearing weight |
Size | 580x400mm |
Display | |
Type | Color TFT (touch screen) |
Size | 10.4 incher |
Resolution | 600x800 pixels |
Work surface light | LED |
LED indication | |
Alarm indication | |
AC power | |
Battery | |
Audio instruction | |
Speaker | Alarm sounds |
Control | |
Button Presskry | |
Interface | |
RS232,VGA,USB | |
Three auxiliary output power | |
interface | |
Moving means | |
Castor | 4 antiastic castors, |
diameter 125mm | |
(2 brake infront) | |
Toolbox | |
Drawer | 200x392x398(HxWxD)x2 |
Respiratory System | |
Air bellow | 1500mL |
Absorption chamber | 1500mL |
Connection | Suction / ACGG ports: |
standard OD 22mm, ID 15mm, | |
tapered connector; | |
Exhalation ports: | |
standard OD 22mm, ID 15mm | |
,tapered connector. | |
Manual breathing port: | |
diameter 22cm | |
System leaks | <40ml/min |
System compliance | Type≤4mL/cmH2O |
Resistance | Inspiratory<0.6kPa |
Expiratory<0.6kPa |
Vaporizer
Parameter | Discription |
Technical Specification | |
Flowrate range | 0.2-15L/min |
Connector type | Selectatec compatible,plug in,cagemount |
Dosing methods | Pour-fil,Easy-fil,Quik-fil(Sevoflurane) |
Working environment | |
Working temperature | +15℃-+35℃ |
Relative humidity | ≤93% |
Atmospheric pressure | 70kPa-106kPa |
Storage temperature | -40℃-+65℃ |
Concentration | 0-5.0% Isoflurane,Enflurane,Halothane 0-8.0% Sevoflurane |
Main Technical Parameters
Parameter | Discription |
Basic function | Disply: 10.4”TFT Touch screen Ventilation Model:VCV,SIMV-V,PCV,Manual,standby. Optional:SIMV-P,PRVC,SIMV-PRVC-PSU(Backup) Tidle Volum:(Optional 20~1500ml) Electronic PEEP,Top light |
Wave form | Paw-T,Flow-T,V-T,CO2-T |
Loop | P-V,V-F(Optional) |
Pressure monitoring | Centrol: O2,N2O,Air Cylinder: O2,N2O |
Monitoring parameter | Tidle Volum,MV, Frequency,:E,Airway Pressue,Pmin,Compliance, Resistance |
Application | Adult and Padiatric |
Vaporizer | Selectic bar for two position |
Gas supply | O2,N2O,Air |
6 tubes flowmeter | O2:0~1OLPM; N2O:0~12LPM; Air: 0~15LPM |
O2% | O2 sensor |
Auxiliary O2 | Auxiliary O2 Flow meter(Oz: 0~15LPM)(Optional |
ACGO | YES |
O2Flush | 25-75L/min |
Battery | NI-MH battery build in.>90mins |
Yoke | 2(O2,N2O)(Optional) |
Gas cylinder | O2,N2O (Optional) |
Cycle absorber | lntergrade, bypass Design,heating system. |
System Specifications | |
Technical Parameters | Specification |
Machine | |
Size | 1410x950x650(HxWxD) |
Weight | 110kg |
Top cover | 30kg bearing weight |
Size | 580x400mm |
Display | |
Type | Color TFT (touch screen) |
Size | 10.4 incher |
Resolution | 600x800 pixels |
Work surface light | LED |
LED indication | |
Alarm indication | |
AC power | |
Battery | |
Audio instruction | |
Speaker | Alarm sounds |
Control | |
Button Presskry | |
Interface | |
RS232,VGA,USB | |
Three auxiliary output power | |
interface | |
Moving means | |
Castor | 4 antiastic castors, |
diameter 125mm | |
(2 brake infront) | |
Toolbox | |
Drawer | 200x392x398(HxWxD)x2 |
Respiratory System | |
Air bellow | 1500mL |
Absorption chamber | 1500mL |
Connection | Suction / ACGG ports: |
standard OD 22mm, ID 15mm, | |
tapered connector; | |
Exhalation ports: | |
standard OD 22mm, ID 15mm | |
,tapered connector. | |
Manual breathing port: | |
diameter 22cm | |
System leaks | <40ml/min |
System compliance | Type≤4mL/cmH2O |
Resistance | Inspiratory<0.6kPa |
Expiratory<0.6kPa |
Vaporizer
Parameter | Discription |
Technical Specification | |
Flowrate range | 0.2-15L/min |
Connector type | Selectatec compatible,plug in,cagemount |
Dosing methods | Pour-fil,Easy-fil,Quik-fil(Sevoflurane) |
Working environment | |
Working temperature | +15℃-+35℃ |
Relative humidity | ≤93% |
Atmospheric pressure | 70kPa-106kPa |
Storage temperature | -40℃-+65℃ |
Concentration | 0-5.0% Isoflurane,Enflurane,Halothane 0-8.0% Sevoflurane |
Main Technical Parameters
Parameter | Discription |
Basic function | Disply: 10.4”TFT Touch screen Ventilation Model:VCV,SIMV-V,PCV,Manual,standby. Optional:SIMV-P,PRVC,SIMV-PRVC-PSU(Backup) Tidle Volum:(Optional 20~1500ml) Electronic PEEP,Top light |
Wave form | Paw-T,Flow-T,V-T,CO2-T |
Loop | P-V,V-F(Optional) |
Pressure monitoring | Centrol: O2,N2O,Air Cylinder: O2,N2O |
Monitoring parameter | Tidle Volum,MV, Frequency,:E,Airway Pressue,Pmin,Compliance, Resistance |
Application | Adult and Padiatric |
Vaporizer | Selectic bar for two position |
Gas supply | O2,N2O,Air |
6 tubes flowmeter | O2:0~1OLPM; N2O:0~12LPM; Air: 0~15LPM |
O2% | O2 sensor |
Auxiliary O2 | Auxiliary O2 Flow meter(Oz: 0~15LPM)(Optional |
ACGO | YES |
O2Flush | 25-75L/min |
Battery | NI-MH battery build in.>90mins |
Yoke | 2(O2,N2O)(Optional) |
Gas cylinder | O2,N2O (Optional) |
Cycle absorber | lntergrade, bypass Design,heating system. |
Three gas supply with 6 tubes flowmeter
O2,N2O,Air, fresh supply, with 5 Gas Supply Pressure Gauges easy monitoring of central gas supplies and gas cylinders status.
Dual DIN rail sys
Adapt patient monitor support arm,BISsYs or syringe pump frame on both sides(Optional)
Cycle absorber assembly
lntegrated bypass cycle absorber withheating system by mold manufacturing,134℃ Sterilization,nature latex free.
Anesthesia Gas Scavenging System
lndependent active AGSS exhaust,avoidanesthesia air pollution in the OR,concerns clinicians healthy (Optional)
Suction
Patient suction system with a regulator andreusable canister (Optional)
Antistatic casters
Diameter 125mm,two brakes of fourcasters.
Top shelf and light
Load weight 30Kg, Height: 1410 mm, Width: 550 Depth: 350,LED light illuminatesall work surfaces
Monitoring interface
Overall parameters of setting,measurement and graphic trends dataintuitive displays.
Anesthesia ventilator
Tidal volume: (Optional 20~1500ml).Easy to upgrade advance ventilationmodes
Friendly interface
10.4"TFT touch screen High resolution,with rotary knob.Resolution 680 x 480
Dual Vaporizer
Select bar support 2 vaporizers position for Enflurane,lsoflurane,Sevoflurane,Halothane VP10 vaporizer compensates for variances in pressure,temperature and flow and needs noannual recalibration.
Yoke
PISS standard, optional max 3 cylinders(Optional)
Drawer
Size: 200 x 392x 398(HxWx D)x2,Optional max 3.
Vaporization
High precision anesthetic vaporizer,service free, dual position with Selectatec bar. Dosage:300ml, available for Halothane,Enflurane, Isoflurane, sevoflurane vaporizer with interlock safe systems.
Compensates for variances in pressure, temperature and flow for accuracy of transmitting concentration ensures
patients receive adequate oxygenation, reliable vaporization of inhaled anesthesia drugs.
Ergonomic integrated breathing circuit
Technology innovation:
A cdosed and semi-closed circuit,PSU material, nature latex free, it is avoid allergic reaction.Fully 134 C autoclavable to avoidcrossinfection, especially for certain respiratory disease operation.
Embed design, flow sensor with variable orifice, suitable for different application from child to adult.
Eficient, integrated heating system,optimized airway design and water trap design to ensure the air fiue without affected by condensation.Also ensure the accuracy of operation for long term.
Bypass design, replacement fo absorber canister fast and convenient, alarm function remind the doctor always and let the operation moresafe and reliable.
Humanized design:
Circuit heating system controls the temperature at35C(t2C) to avoid condensate water effect on the flow sensor lifetime and accuracy; alsomake the patient feel more comfortable.
Bypass design enable fast and convenient replacement of COr canister without stopping operation. Special designed chamberassembly monitoring to avoid misoperation.
Easy for installing cleaning disinfecting and maintaining without any tools and training.
Ventilation
The large color LCD screen displays all ventilator's setting data, measurement information, loops and numeric l graphic trends. Standard Active Exhalation Valve,Electronic flowmeter.
Sufficient modes of Ventilation, Volume Control, Pressure Control, SIM (Volume and Pressure),CPAP / PSV and manual
With Tidal volume 20ml which could apply adults and infant.
Optional Auxiliary oxygen flowmeter and famous brand SPO2,EtCOz provide more monitoring reference for droctor
Ergonomics design anesthesia machine
More convenient operating and display systems for clinical operations; Suitable for a wide range of anesthesia
adult and pediatric. (Tidal volume Optional 20~1500ml)
Electronic PEEP, lmported proportional valve, traditional 6 tubes flowmeter, all ensure the excellent performance,durable, long-term use.
Highly integrated circuits, the overall heat auto circuit technology to avoid condensation circuit; by-pass bypass function,the canister can be replaced in the course of anesthesia, no harmful gas leakage.
Sufficient monitoring parameter: Ppeak, Pmean, Pmin, Pplat, PEEP Compliance,Resistance,0:%,EtCOz FiCO
Clinician's health concerns: Independent AGss exhaust vent and active sewage systems avoid anesthesia gas pollution.
Complete alarm function to make sure the operation accuracy and stability.
Three gas supply with 6 tubes flowmeter
O2,N2O,Air, fresh supply, with 5 Gas Supply Pressure Gauges easy monitoring of central gas supplies and gas cylinders status.
Dual DIN rail sys
Adapt patient monitor support arm,BISsYs or syringe pump frame on both sides(Optional)
Cycle absorber assembly
lntegrated bypass cycle absorber withheating system by mold manufacturing,134℃ Sterilization,nature latex free.
Anesthesia Gas Scavenging System
lndependent active AGSS exhaust,avoidanesthesia air pollution in the OR,concerns clinicians healthy (Optional)
Suction
Patient suction system with a regulator andreusable canister (Optional)
Antistatic casters
Diameter 125mm,two brakes of fourcasters.
Top shelf and light
Load weight 30Kg, Height: 1410 mm, Width: 550 Depth: 350,LED light illuminatesall work surfaces
Monitoring interface
Overall parameters of setting,measurement and graphic trends dataintuitive displays.
Anesthesia ventilator
Tidal volume: (Optional 20~1500ml).Easy to upgrade advance ventilationmodes
Friendly interface
10.4"TFT touch screen High resolution,with rotary knob.Resolution 680 x 480
Dual Vaporizer
Select bar support 2 vaporizers position for Enflurane,lsoflurane,Sevoflurane,Halothane VP10 vaporizer compensates for variances in pressure,temperature and flow and needs noannual recalibration.
Yoke
PISS standard, optional max 3 cylinders(Optional)
Drawer
Size: 200 x 392x 398(HxWx D)x2,Optional max 3.
Vaporization
High precision anesthetic vaporizer,service free, dual position with Selectatec bar. Dosage:300ml, available for Halothane,Enflurane, Isoflurane, sevoflurane vaporizer with interlock safe systems.
Compensates for variances in pressure, temperature and flow for accuracy of transmitting concentration ensures
patients receive adequate oxygenation, reliable vaporization of inhaled anesthesia drugs.
Ergonomic integrated breathing circuit
Technology innovation:
A cdosed and semi-closed circuit,PSU material, nature latex free, it is avoid allergic reaction.Fully 134 C autoclavable to avoidcrossinfection, especially for certain respiratory disease operation.
Embed design, flow sensor with variable orifice, suitable for different application from child to adult.
Eficient, integrated heating system,optimized airway design and water trap design to ensure the air fiue without affected by condensation.Also ensure the accuracy of operation for long term.
Bypass design, replacement fo absorber canister fast and convenient, alarm function remind the doctor always and let the operation moresafe and reliable.
Humanized design:
Circuit heating system controls the temperature at35C(t2C) to avoid condensate water effect on the flow sensor lifetime and accuracy; alsomake the patient feel more comfortable.
Bypass design enable fast and convenient replacement of COr canister without stopping operation. Special designed chamberassembly monitoring to avoid misoperation.
Easy for installing cleaning disinfecting and maintaining without any tools and training.
Ventilation
The large color LCD screen displays all ventilator's setting data, measurement information, loops and numeric l graphic trends. Standard Active Exhalation Valve,Electronic flowmeter.
Sufficient modes of Ventilation, Volume Control, Pressure Control, SIM (Volume and Pressure),CPAP / PSV and manual
With Tidal volume 20ml which could apply adults and infant.
Optional Auxiliary oxygen flowmeter and famous brand SPO2,EtCOz provide more monitoring reference for droctor
Ergonomics design anesthesia machine
More convenient operating and display systems for clinical operations; Suitable for a wide range of anesthesia
adult and pediatric. (Tidal volume Optional 20~1500ml)
Electronic PEEP, lmported proportional valve, traditional 6 tubes flowmeter, all ensure the excellent performance,durable, long-term use.
Highly integrated circuits, the overall heat auto circuit technology to avoid condensation circuit; by-pass bypass function,the canister can be replaced in the course of anesthesia, no harmful gas leakage.
Sufficient monitoring parameter: Ppeak, Pmean, Pmin, Pplat, PEEP Compliance,Resistance,0:%,EtCOz FiCO
Clinician's health concerns: Independent AGss exhaust vent and active sewage systems avoid anesthesia gas pollution.
Complete alarm function to make sure the operation accuracy and stability.
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634