Anesthesia Workstation AKIA
Home » Products » Surgery & Life Support » Anesthesia Unit » Anesthesia Workstation AKIA

Product Category

loading

Share to:
sharethis sharing button

Anesthesia Workstation AKIA

Availability:
Quantity:

1. More convenient operating and display systems for clinical operations; Suitable fora wide range of anesthesia: adult and pediatric.(Tidal volume Optional 20~1500ml)

2. Electronic PEEP,Imported proportional valve, traditional 6 tubes flowmeter, allensure the excellent performance,durable, long-term use.

3. Highly integrated circuits,the overall heat auto circuit technology to avoidcondensation circuit; by-pass bypass function,the canister can be replaced in thecourse of anesthesia, no harmful gas leakage.

4. Sufficient monitoring parameter: Ppeak,Pmean,Pmin,Pplat,PEEP Compliance,Resistance,O2%, EtCO2,FiCO2.

5. Clinician's health concerns: Independent AGSS exhaust vent and active sewagesystems avoid anesthesia gas pollution.

6.Complete alarm function to make sure the operation accuracy and stability.


System Specifications
Technical ParametersSpecification
Machine
Size
1410x950x650(HxWxD)
Weight110kg
Top cover30kg bearing weight
Size
580x400mm
Display
TypeColor TFT (touch screen)
Size
10.4 incher
Resolution600x800 pixels
Work surface lightLED
LED indication

Alarm indication 

AC power

Battery
Audio instruction
Speaker
Alarm sounds
Control

Button Presskry
Interface

RS232,VGA,USB

Three auxiliary output power

interface
Moving means
Castor
4 antiastic castors,

diameter 125mm

(2 brake infront)
Toolbox
Drawer
200x392x398(HxWxD)x2
Respiratory System
Air bellow
1500mL
Absorption chamber1500mL
Connection
Suction / ACGG ports:

standard OD 22mm, ID 15mm,

tapered connector;

Exhalation ports:

standard OD 22mm, ID 15mm

,tapered connector.

Manual breathing port:

diameter 22cm
System leaks
<40ml/min
System complianceType≤4mL/cmH2O
Resistance
Inspiratory<0.6kPa

Expiratory<0.6kPa


Vaporizer

ParameterDiscription
Technical Specification
Flowrate range0.2-15L/min
Connector typeSelectatec compatible,plug in,cagemount
Dosing methodsPour-fil,Easy-fil,Quik-fil(Sevoflurane)
Working environment
Working temperature+15℃-+35℃
Relative humidity
≤93%
Atmospheric pressure70kPa-106kPa
Storage temperature-40℃-+65℃


Concentration

0-5.0%

Isoflurane,Enflurane,Halothane

0-8.0%

Sevoflurane


Main Technical Parameters

ParameterDiscription



Basic function

Disply: 10.4”TFT Touch screen

Ventilation Model:VCV,SIMV-V,PCV,Manual,standby.

Optional:SIMV-P,PRVC,SIMV-PRVC-PSU(Backup)

Tidle Volum:(Optional 20~1500ml)

Electronic PEEP,Top light

Wave form

Paw-T,Flow-T,V-T,CO2-T

LoopP-V,V-F(Optional)


Pressure monitoring

Centrol: O2,N2O,Air

Cylinder: O2,N2O

Monitoring parameter

Tidle Volum,MV, Frequency,:E,Airway Pressue,Pmin,Compliance, Resistance

ApplicationAdult and Padiatric
Vaporizer

Selectic bar for two position

Gas supplyO2,N2O,Air


6 tubes flowmeter

O2:0~1OLPM;

N2O:0~12LPM;

Air: 0~15LPM

O2%O2 sensor
Auxiliary O2

Auxiliary O2 Flow meter(Oz: 0~15LPM)(Optional

ACGOYES
O2Flush25-75L/min
Battery

NI-MH battery build in.>90mins

Yoke

2(O2,N2O)(Optional)

Gas cylinder

O2,N2O (Optional)

Cycle absorber

lntergrade, bypass Design,heating system.



Three gas supply with 6 tubes flowmeter

O2,N2O,Air, fresh supply, with 5 Gas Supply Pressure Gauges easy monitoring of central gas supplies and gas cylinders status.



Dual DIN rail sys

Adapt patient monitor support arm,BISsYs or syringe pump frame on both sides(Optional)


QQ截图20221231184103


Cycle absorber assembly

lntegrated bypass cycle absorber withheating system by mold manufacturing,134℃ Sterilization,nature latex free.

QQ截图20221231184123


Anesthesia Gas Scavenging System

lndependent active AGSS exhaust,avoidanesthesia air  pollution in the OR,concerns clinicians healthy (Optional)

QQ截图20221231184130


Suction

Patient suction system with a regulator andreusable canister (Optional)

QQ截图20221231184137



Antistatic casters

Diameter 125mm,two brakes of fourcasters.

QQ截图20221231184143


Top shelf and light

Load weight 30Kg, Height: 1410 mm, Width: 550 Depth: 350,LED light illuminatesall work surfaces


Monitoring interface

Overall parameters of setting,measurement and graphic trends dataintuitive displays.

QQ截图20221231184158


Anesthesia ventilator

Tidal volume: (Optional 20~1500ml).Easy to upgrade advance ventilationmodes


Friendly interface

10.4"TFT touch screen High resolution,with rotary knob.Resolution 680 x 480

QQ截图20221231184205


Dual Vaporizer

Select bar support 2 vaporizers position for Enflurane,lsoflurane,Sevoflurane,Halothane VP10 vaporizer compensates for variances in pressure,temperature and flow and needs noannual recalibration.

QQ截图20221231184211


Yoke

PISS standard, optional max 3 cylinders(Optional)

QQ截图20221231184218


Drawer

Size: 200 x 392x 398(HxWx D)x2,Optional max 3.


Vaporization


High precision anesthetic vaporizer,service free, dual position with Selectatec bar. Dosage:300ml, available for Halothane,Enflurane, Isoflurane, sevoflurane vaporizer with interlock safe systems.

Compensates for variances in pressure, temperature and flow for accuracy of transmitting concentration ensures

patients receive adequate oxygenation, reliable vaporization of inhaled anesthesia drugs.

QQ截图20221230162101

Ergonomic integrated breathing circuit


Technology innovation:

A cdosed and semi-closed circuit,PSU material, nature latex free, it is avoid allergic reaction.Fully 134 C autoclavable to avoidcrossinfection, especially for certain respiratory disease operation.

Embed design, flow sensor with variable orifice, suitable for different application from child to adult.

Eficient, integrated heating system,optimized airway design and water trap design to ensure the air fiue without affected by condensation.Also ensure the accuracy of operation for long term.

Bypass design, replacement fo absorber canister fast and convenient, alarm function remind the doctor always and let the operation moresafe and reliable.


Humanized design:

Circuit heating system controls the temperature at35C(t2C) to avoid condensate water effect on the flow sensor lifetime and accuracy; alsomake the patient feel more comfortable.

Bypass design enable fast and convenient replacement of COr canister without stopping operation. Special designed chamberassembly monitoring to avoid misoperation.

Easy for installing cleaning disinfecting and maintaining without any tools and training.


Ventilation


The large color LCD screen displays all ventilator's setting data, measurement information, loops and numeric l graphic trends. Standard Active Exhalation Valve,Electronic flowmeter.

Sufficient modes of Ventilation, Volume Control, Pressure Control, SIM (Volume and Pressure),CPAP / PSV and manual

With Tidal volume 20ml which could apply adults and infant.

Optional Auxiliary oxygen flowmeter and famous brand SPO2,EtCOz provide more monitoring reference for droctor


Ergonomics design anesthesia machine


More convenient operating and display systems for clinical operations; Suitable for a wide range of anesthesia

adult and pediatric. (Tidal volume Optional 20~1500ml)

Electronic PEEP, lmported proportional valve, traditional 6 tubes flowmeter, all ensure the excellent performance,durable, long-term use.

Highly integrated circuits, the overall heat auto circuit technology to avoid condensation circuit; by-pass bypass function,the canister can be replaced in the course of anesthesia, no harmful gas leakage.

Sufficient monitoring parameter: Ppeak, Pmean, Pmin, Pplat, PEEP Compliance,Resistance,0:%,EtCOz FiCO

Clinician's health concerns: Independent AGss exhaust vent and active sewage systems avoid anesthesia gas pollution.

Complete alarm function to make sure the operation accuracy and stability.