Characteristics
The steam can't go through to chamber when the door don't close, and the pilot off inform.You can process dry operation.
When the pressure inner over o,027MPa.the door be locked and can't be open.
lf you not choose the sterilize time and start the machine, buzzer sound will be alarm.
Opening the door by mistake in the course of start, the jacker valve and chamber valve will auto shut-off.
Lacking water the pilot light on, heating and sterilize pilot light off, the buzzer sound and auto release steam.
Overload and leakage protection,when leakage or over current occur, it auto off the power.
Temperature controlled not work and the inner pressure over 0.165MPa, the safety valve auto start open.
Technical Data
Technical data | AS-150YDA | AS-200YDA | AS-280YDA | AS-400YDA | AS-500YDA |
Sterilizing chamber | 150L | 200L | 280L | 400L | 500L |
volume | φ440×1000mm | φ515×1000mm | φ600×1000mm | Φ700×1100mm | Φ700×1300mm |
working pressure | 0.22MPa | ||||
working temperature | 134℃ | ||||
Adjustment of temperature | 105℃ - 134℃ | ||||
Time of sterilization | 0-60 min | ||||
Time of drying | 0-60 min | ||||
Heat average | ≤±1℃ | ||||
Power | 9KW/380V 50Hz | 9KW/380V 50Hz | 12KW/380V 50Hz | 18KW/380V 50Hz | 18KW/380V 50Hz |
Dimension | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 | 1800×900×1820 |
Transport dimension | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1800×1050×2100 | 1850×1050×2100 |
G.W/N.W | 320/240 KG | 350/260 KG | 465/365 KG | 530/520 KG | 580/470 KG |
Characteristics
The steam can't go through to chamber when the door don't close, and the pilot off inform.You can process dry operation.
When the pressure inner over o,027MPa.the door be locked and can't be open.
lf you not choose the sterilize time and start the machine, buzzer sound will be alarm.
Opening the door by mistake in the course of start, the jacker valve and chamber valve will auto shut-off.
Lacking water the pilot light on, heating and sterilize pilot light off, the buzzer sound and auto release steam.
Overload and leakage protection,when leakage or over current occur, it auto off the power.
Temperature controlled not work and the inner pressure over 0.165MPa, the safety valve auto start open.
Technical Data
Technical data | AS-150YDA | AS-200YDA | AS-280YDA | AS-400YDA | AS-500YDA |
Sterilizing chamber | 150L | 200L | 280L | 400L | 500L |
volume | φ440×1000mm | φ515×1000mm | φ600×1000mm | Φ700×1100mm | Φ700×1300mm |
working pressure | 0.22MPa | ||||
working temperature | 134℃ | ||||
Adjustment of temperature | 105℃ - 134℃ | ||||
Time of sterilization | 0-60 min | ||||
Time of drying | 0-60 min | ||||
Heat average | ≤±1℃ | ||||
Power | 9KW/380V 50Hz | 9KW/380V 50Hz | 12KW/380V 50Hz | 18KW/380V 50Hz | 18KW/380V 50Hz |
Dimension | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 | 1800×900×1820 |
Transport dimension | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1800×1050×2100 | 1850×1050×2100 |
G.W/N.W | 320/240 KG | 350/260 KG | 465/365 KG | 530/520 KG | 580/470 KG |