Technical specifications
Monophaisc
Technical specifications
DEFIBRILLATOR.
(1) Defibrillator type Manual, Synchronized, Asynchronized,
(2) Energy accuracy ∠+1%
(3) Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4) Charging time Maximum 10 seconds to 360 Joules
(5) Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
.Power requirements.
(a) AC Power supply 100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option) DC 12V
Internal Battery Backup
(1) Battery type Rechargeable lead-acid battery (12V 2.0Ah X2)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120-min monitoring; and 35 discharges at 360 joules.
Display
-LCD Dimensions 7-inch
-Type High resolution true-color graphic
-Resolution 480X234
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45℃
Resolution 0.1℃
Pulse Oximetry(spO2)
Display :spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
Technical specifications
Monophaisc
Technical specifications
DEFIBRILLATOR.
(1) Defibrillator type Manual, Synchronized, Asynchronized,
(2) Energy accuracy ∠+1%
(3) Energy selection 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules (nominal at a resistance of 50)
(4) Charging time Maximum 10 seconds to 360 Joules
(5) Standard Adult/Pediatric Paddles Reusable external adult paddles (pediatric paddles integrated)
.Power requirements.
(a) AC Power supply 100V~240V,50Hz/60 Hz
(b) Vehicle Voltage(Option) DC 12V
Internal Battery Backup
(1) Battery type Rechargeable lead-acid battery (12V 2.0Ah X2)
(2) Charging time Time-Minimum of 4 hours for full charging
(3) Battery charging During AC Power Supply operation of the device.
(4) Charging /Low Battery Indication Red LED
(5) Battery Capacity 100% of the battery will provide 120-min monitoring; and 35 discharges at 360 joules.
Display
-LCD Dimensions 7-inch
-Type High resolution true-color graphic
-Resolution 480X234
ECG
ECG lead: Ⅰ, Ⅱ, Ⅲ, AVR, AVL, AVF, V1~V6
S-T segment analysis: -2.0~2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000vAc/50Hz voltage in isolation and work against electrosurgical knife and defibrillation
Respiration
Measurement method: Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method: Automatic oscillation
Cuff type: standard Adult; optional Pediatric/Neonatal
Temperature
Measurement range 20~45℃
Resolution 0.1℃
Pulse Oximetry(spO2)
Display :spo2 value, pulse histogram, waveform, Pulse
Range: 0~99%for adult, pediatric and neonatal patients
Probe :standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter & configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder, Li-ion battery (11.1V 4Ah X2)
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634