ARM-8TC Color Ultrasonic Diagnostic Machine
Home » Products » Medical Imaging System » Ultrasound Scanner » ARM-8TC Color Ultrasonic Diagnostic Machine

Product Category

loading

Share to:
sharethis sharing button

ARM-8TC Color Ultrasonic Diagnostic Machine

ARM-8TC Color Ultrasonic Diagnostic Machine
Availability:
Quantity:

Color Ultrasonic Diagnostic Apparatus

1

Summary of main specifications and system of cart type color Doppler ultrasound



1.1

Trolley type all digital color Doppler ultrasonic mainframe



1.2

Ultrasonic host operating system: Windows operating system



1.3

Applications

Abdomen, obstetrics, gynecology, heart, urinary system, small organs, superficial, blood vessels, pediatrics, newborns, musculoskeletal



1.4

Probes

Convex probe, Tran-vaginal probe, Linear probe, Micro-convex probe, Cardiac probe,4D Volume

probe



1.5

Applications and report

Abdominal,OB,GYN,Cardiac,Urinary,Small Parts,Superficial, Vascular, Pediatrics, Advanced measurement software packages, report software packages, case management software packages, etc.



☆1.6

carotid artery intima measurement thickness(IMT



☆1.7

Automatic spectral envelope measurement



1.8

Full digital transmission and reception of beam synthesizer



1.9

Color Doppler imagingC



1.10

Pulse Doppler ImagingPW



☆1.12

Coherent Contrast imagingCCI



1.12

Continuous wave Doppler imagingCW



☆1.13

B/C/D Real-time three synchronous imaging



☆1.14

Power Doppler imagingPDI



☆1.15

Direct power Doppler imagingDPDI



1.16

M mode imaging



☆1.17

Anatomic M mode imaging



☆1.18

Color Doppler M mode imaging



1.19

Elastography



☆1.20

Tissue Doppler imagingTDI



☆1.21

Strain rate imaging (SRI)



1.22

Tissue harmonic imagingTHI



1.23

Fusion harmonic imagingFHI



1.24

Speckle Reduce imagingSRI



☆1.25

Panoramic imaging



1.26

Deflection imaging



1.27

Trapezoidal imaging



1.28

Adaptive velocity optimization



☆1.29

Free hand 3D



1.30

Real time 3D imaging3D/4D



1.31

DICOM3.0



1.32

Monitor21.5 inchhigh definition ultrasonic display



1.33

13.3 inch touch screen



1.34

Physical clipboard: save the image on the left side of the screen, which can be directly saved or deleted.



1.35

The system has the function of on-the-spot upgrade



1.36

Presupposition: for different inspection of the viscera, preset the inspection conditions for the best image, reduce the adjustment of the operation, and the commonly used external adjustment and combination regulation.



1.37

Probe interface: 4



1.38

Chinese and English System, Chinese and English input, optional



1.39

Depth≥360mm



1.40

Extended imaging



2

Probes



2.1      Convex probe

Fundamental Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/4.6MHz/5.0MHz/5.4MHz,

Harmonic Frequency

4.0MHz/4.6MHz/5.0MHz



2.2      

Linear probe

Fundamental Frequency4.0MHz/4.6MHz/5.0MHz/6.0MHz/7.0MHz/8.0MHz/9.2MHz/10.0MHz/12.0MHz/13.3MHz

Harmonic Frequency

8.0MHz/9.2MHz/10.0MHz,



2.3 Trans-vaginal probe

Fundamental Frequency

3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz/10.0MHz

Harmonic Frequency

6.0MHz/7.0MHz/8.0MHz



2.4 Micro-convex probe

Fundamental Frequency

3.0MHz/3.5MHz/4.0MHz/5.0MHz/5.4MHz/6.0MHz/7.0MHz/8.0MHz

Harmonic Frequency

6.0MHz/7.0MHz/8.0MHz



2.5      Cardiac probe

Fundamental Frequency1.7MHz/1.9MHz/2.1MHz/2.5MHz/3.0MHz/3.4MHz/3.8MHz/4.2MHz/5.0MHz

Harmonic Frequency

3.4MHz/3.8MHz/4.2MHz



2.6      

4D Volume probe

Fundamental Frequency

2.0MHz/2.5MHz/3.0MHz/3.3MHz/3.7MHz/4.0MHz/5.0MHz/6.0MHz

Harmonic Frequency

4.0MHz/5.0MHz/6.0MHz



3

2D imaging mode



3.1

Gain0100Step 2 adjustable



3.2

TGC8 segment adjustable



3.3

Maximum focus point≥7, which can be moved throughout the whole process.



3.4

Speckle reduction0-55 level



3.5

Space Synthesis0-22 levelLiner probe: 3 levelcardiac probe:0



3.6

Dynamic30-18035 levelstep 5 adjustable



3.7

Line densitylowmiddlehigh3 level



3.8

Frame correlation0-4,4 level



3.9

Noise reduction0-55 level



3.10

Edge Enhancement0-55 level



3.11

Sound power2-10, 9 level



3.12

Grey scale0-67, 67 level



3.13

False color0-6767 level



3.14

Image styleSoft-Comparison2 level




The screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted



4

Color Doppler imaging mode



4.1

Blood gain0-100Step 2



4.2

Parameter displayVelocityVariance



4.3

B-RestrainB/W restrain):0-7, 7 level



4.4

Speed Through0-8, 8 level



4.5

Sampling number6-24, 7 level



4.6

Blood flow preferred0-8, 8 level



4.7

Filtering1-6, 6 level



4.8

Sound power2-6, 4 level


4.9

Noise reduction0-4, 4 level


4.10

Smooth treatment0-44 level


4.11

Frame correlation0-66 level


4.12

ChromatographyBlood flow graph):0-3737 level


4.13

Line densityLow-Middle-High3 level


4.14

Frequency4 level adjustable


4.15

VelocityMinimum 0.4KMaximum 40.5K

Convex probe0.4K-4.3K-38.5K

Linear probe0.4K-14.7K-39.0K

Trans-vaginal probe0.4K-7.8K-39.7K

Volume probe0.4K-4.2K-34.8K

Micro-convex probe0.4K-10.3K-40.5K

cardiac probe0.4K-7.8K-39.7K



PSThe frequency of the probe changes and the frequency value changes



PSFrame rate changes with speed


5

Pulse wave DopplerPW


1

Gain0-100Step 2


5.2

Spectrum envelope function: real time automatic spectrum envelope, manual spectrum envelope, and other modes. The system automatically analyses and displays various data such as PSV, EDV, RI, PI, S/D, ACC, HR and so on. Can wake up or close


5.3

Sample volume0.5mm~30mm


5.4

Blood angel-75—75 degreeStep 5


5.5

False color0-6767 level


5.6

Dynamic range20-404 level


5.7

Filter0-9, 9 level


5.8

Smooth treatment1-44 level


5.9

Sound power2-54 level


5.10

Volume0-100, 10 levelStep 10


5.11

Audio filtering0-44 level


5.12

Base line-1.0~1.0,


5.13

Grey map0-6767 level


5.14

Scan velocity100-500, 6 level


5.15

PRF:Minimum 0.5KMaximum 87.5K

Convex probe0.5K-4.3K-63.3K

Linear probe0.5K-14.5K-78.4K

Trans-vaginal probe0.5K-8.1K-78.4K

Volume probe0.5K-4.2K-53.8K

Micro-convex probe0.5K-10.3K-81.1K

cardiac probe0.5K-4.3K-87.5K


5.16

Frequency4 level



PSThe frequency of the probe changes and the PRF value changes



PSThe frequency of the probe changes and the frequency value changes


6

Continuous Wave DopplerCW


6.1

Support probeCardiac probe


6.2

Adjustment of B mode parameters is switchable


6.3

Gain0-100Step 2


6.4

Sampling line position is adjustable


6.5

PRF:0.9K~36.1K


6.6

Baseline-1.0~1.0


6.7

Blood angel-75~75 degree


6.8

Grey map0-67


6.9

Scan velocity100-300


6.10

False color0-67


6.11

Dynamic range20-40


6.12

Filtering0-99 level


6.13

Smooth treatment1-4


6.14

Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz4 level adjustable


6.15

Sound power2-5


6.16

Volume0-100


6.17

Audio Filtering0-4


☆7

Anatomical M imaging


7.1

Support probeConvex probe, Linear probe,Cardiac probe


7.2

Adjustment of B mode parameters is switchable


7.3

Gain0-100Step 2


7.4

M Sampling line angel is adjustable


7.5

M Sampling line length is adjustable


7.6

Sampling line3Can be displayed or hidden separately


☆8

Blood flow M modelMC


8.1

Adjustment of B mode parameters is switchable


8.2

Gain0-100Step2


8.3

MC Sampling line angel is adjustable


8.4

MC Sampling line length is adjustable


8.5

Frequency4 level


8.6

Sampling number6-24


8.7

Speed through0-8, 8 level


8.8

Scan velocity150-500


8.9

Frame correlation0-6, 6 level


8.10

Filtering1-66 level


8.11

Blood flow preferred0-88 level


8.12

Smooth treatment0-4,4 level


8.13

Map0-37, 37 level


☆9

Elastography


9.1

Adjustment of B mode parameters is switchable


9.2

Gain0-100Step 2


9.3

B/EDouble real-time display on the same screen


9.4

Probe displacement curve displayUp/Down


9.5

Pressure indicator bar display


9.6

Frequency8-9 levelAdjustableAccording to the probe display


9.7

Noise reduction0-2, 2 level


9.8

Frame correlation0-3, 3 level


9.9

Comparison0-13, 13 level


9.10

False color0-33 level


9.11

Don’t support cardiac probe


☆10

Tissue Doppler imagingTDI


10.1

Support probe: Cardiac probe


10.2

Adjustment of B mode parameters is switchable


10.3

Gain0-100step 2


10.4

ROI area adjustable


10.5

Sampling number6-24


10.6

Velocity0.4K-8.0K


10.7

Frame correlation0-66


10.8

Tissue preferred0-7, 7 level


10.9

Frequency2.0MHz/2.3MHz/2.5MHz/3.0MHz


10.10

Support color reversal


☆11

Strain rate imaging


11.1

Support probe: Cardiac probe


11.2

Adjustment of B mode parameters is switchable


11.3

ROI area adjustable


11.4

Gain0-100Step 2


11.5

Sampling number6-246 level


11.6

Axial average1-44 level


11.7

Velocity0.4K-8K


11.8

Frame correlation0-66 level


11.9

Tissue optimization0-77 level


☆12

Panoramic imaging


12.1

Support probeLinear probe


12.2

Speckle Reduction0-5, 5 level


☆13

Deflection imaging



13.1

Support probeLinear probe



13.2

Adjustment of B mode parameters is switchable



13.3

Deflection angel8 level



13.4

Speckle reduction0-5, 5 level



13.5

Dynamic rate30-180Step 5



13.6

Line densitylow-middle-high3 level



13.7

Frame Correlation0-44 level



13.8

False color0-67, 67 level



13.9

Image styleSoft-Comparison2 level



13.10

Noise reduction0-5, 5 level



13.11

Edge Enhancement0-55 level



13.12

Sound power2-108 level



13.13

Grey map0-6767 level



☆14

Trapezoidal imaging



14.1

Probe supportlinear probe



14.2

Adjustment of B mode parameters is switchable



14.3

Deflection angel8 level



14.4

Speckle reduction0-5, 5 level



14.5

Dynamic rate30-180Step 5



14.6

Line densitylow-middle-high3 level



14.7

Frame Correlation0-44 level



14.8

False color0-67, 67 level



14.9

Image styleSoft-Comparison2 level



14.10

Noise reduction0-5, 5 level



14.11

Edge Enhancement0-55 level



14.12

Sound power2-108 level



14.13

Grey map0-6767 level



14.14

Space Synthesis0-2, 2 level



☆15

Freehand 3D imaging


15.1

Support probeconvex probe, linear probe


15.2

Display model: 4 pictures


15.3

Image Rotation X/Y/Z Axis


15.4

Multi-slice Visibility


16

Real-time 4D imaging


16.1

Support probe: 4D volume probe


16.2

Adjustment of B mode parameters is switchable


16.3

Gain0-100Step 2


16.4

Display modelone imagetwo imagesfour images


16.5

Image RotationX/Y/Z Axis


16.6

Multi-slice Visibility


16.7

Light&Shade inversion


16.8

Smooth0-4, 4 level


16.9

Threshold level0-129, Step 3


16.10

Transparency1-509Step 10


16.11

Render type4 kindsSurfacemaximumminimumperspective


17

Extended Imaging



17.1

Gain0100Step 2



17.2

TGC8 segment adjustable



17.3

Maximum focus point≥7, which can be moved throughout the whole process.



17.4

Speckle reduction0-55 level



17.5

Space Compound0-22 levelLinear probe: 3 leveldon’t support cardiac probe



17.6

Dynamic range30-18035 levelStep 5



17.7

Line densityLowMiddleHigh3 level



17.8

Frame correlation0-4,4 level



17.9

Noise reduction0-55 level



17.10

Edge enhancement0-55 level



17.11

Sound power2-10, 9 level



17.12

Grey map0-67, 67 level



17.13

False color0-6767 level



17.14

Image styleSoft-Comparison2 level



17.15

Extended level: Maximum 72 level

Convex probe9 level

Trans-vaginal probe72 level

Micro-convex probe29 level

Cardiac probe40 level

4D Volume probe17 level




PSThe screen has real-time display of voice power, probe frequency, dynamic range, pseudo color, gray scale and other 11 parameters can be adjusted



PS: When the probe scan range reaches the maximum, the space synthesized is 0.


18

Measurement and analysis function:


18.1

General measurement: Distance, area, ellipse, cross line, angle, distance ratio, volume, Volume (ellipse), area ratio, diameter, joint angle


18.2

CardiacAutomatic spectrum envelopeLVMain Pulmonary artery diameterRVEDdRVEDsLVMLAVHRMVFAOARLVOTTVFPulmonic valvePulmonary veinRVDoppler fetal heart soundLVETLVMLVMIAV


18.3

Vascular: carotid intima (IMT), length stenosis ratio, area stenosis ratio, IMT (back wall), IMT (front wall)


18.4

OBFetal routineAFITWGSCRlOFDHLulnaNTFibulaNbonelRadialTibia


18.5

GYNuteruscervixcorpus uteri/cervix uterusleft ovarian veinright ovarian veindominant follicleintima thickness


18.6

Urology: prostateresidual urineleft kidneyright kidneyleft suprarenal veinright suprarenalleft testisright testisleft seminal vesicleright seminal vesicle


18.7

AbdomenliverCHDpartal vein diametercholecystCBDpancreasspleenInternal diameter of abdominal aortakidney


18.8

Small partsThyroid


18.9

Software packageMeasurement packageSoftware packageMedical records management software package


19

Graphic and text management system


19.1

Host build in 2 hard diskSSD 120+1T),Start fast and stable


19.2

Movie playback≥1200 frames


19.3

Internal file information management system: can record patient number, name, check number, check date and so on, and can be searched and managed by numbering, checking number, name and so on.


19.4

Type of report is 16


19.5

One key fast report graphic and text management


20

Interface


20.1

USB interface4


20.2

HDMI interface1


20.3

RJ-45 interface1


20.4

Grounding wire interface1


20.5

DVD RW1


 21

Configuration


21.1

Trolley type full digital color Doppler ultrasound diagnostic system


21.2

Probe: convex array probe (standard), linear probe (optional), Trans-vaginal probe (optional), cardiac probe (optional), 4D volume probe (optional)


21.3

≥13 quick adjusting knobs


22:

Technology, after-sales service and other requirements


22.1

After acceptance, the warranty is free for two yearsProvide manufacturer warranty certificate


22.2

Manufacturer has ISO13485 certification and EU CE certification.





 