ARM-2C
ARCHMED
ARM-2C is a multi-functional anesthesia machine incorporating anesthesia, respiratory and monitoring functions.
Anesthesia Machine: Two-stage pressure relief; high-precision N2Oand O2 flowmeters. ORC, O2-deficiency alarm and N2O cut-off device. It′s equipped with ZFG-B1 compensation vaporizer or fit for other brand vaporizer such ad Drager one or GE’s.
Integrated breathing system satisfies clinical demand of low-flow anesthesia.
Anesthesia Ventilator: Pneumatic-driven and electric-controlled, time-cycled and volume-constant.
Low air-consumption. Power failure alarm and low-flow alarm.
Monitor: Equipped with respiratory monitory for real-time monitor on tidal volume, minute volume, respiratory frequency and oxygen concentration assuring patients safety.
Specification
● Adjustment range of flow :O2:0.02-15L/min
N2O: 0.02-10L/min
ORC: O2 concentration≥25%(O2+N2O)
● O2 Flush: 25-75L/min
● O2 deficiency alarm/N2Ocut-off:
As O2 pressure is≤0.2Mpa,audible;
As O2 pressure is≤0.14Mpa,N2O decrease;
As O2 pressure is≤0.04Mpa,N2O is cut off automatically;
● APL adjustment:0.5 -7kPa;CO2 absorber:1.6L
● Vaporizer:0-6VOL%,with pressure,flow and temperature
compensation functions.
● Anesthesia ventilator:
Frequency:6-40bpm:
Tidal volume:50-1400ml
1:E:1:0.2-1:9.9,adjustable
Maximum airway pressure:6kpa
● Respiratory monitor:
Tidal volume:50-1500ml
MV: 6-40L/min
Oxygen concentration:21-100%
Airway Pressure:0-9.9kpa
ARM-2C is a multi-functional anesthesia machine incorporating anesthesia, respiratory and monitoring functions.
Anesthesia Machine: Two-stage pressure relief; high-precision N2Oand O2 flowmeters. ORC, O2-deficiency alarm and N2O cut-off device. It′s equipped with ZFG-B1 compensation vaporizer or fit for other brand vaporizer such ad Drager one or GE’s.
Integrated breathing system satisfies clinical demand of low-flow anesthesia.
Anesthesia Ventilator: Pneumatic-driven and electric-controlled, time-cycled and volume-constant.
Low air-consumption. Power failure alarm and low-flow alarm.
Monitor: Equipped with respiratory monitory for real-time monitor on tidal volume, minute volume, respiratory frequency and oxygen concentration assuring patients safety.
Specification
● Adjustment range of flow :O2:0.02-15L/min
N2O: 0.02-10L/min
ORC: O2 concentration≥25%(O2+N2O)
● O2 Flush: 25-75L/min
● O2 deficiency alarm/N2Ocut-off:
As O2 pressure is≤0.2Mpa,audible;
As O2 pressure is≤0.14Mpa,N2O decrease;
As O2 pressure is≤0.04Mpa,N2O is cut off automatically;
● APL adjustment:0.5 -7kPa;CO2 absorber:1.6L
● Vaporizer:0-6VOL%,with pressure,flow and temperature
compensation functions.
● Anesthesia ventilator:
Frequency:6-40bpm:
Tidal volume:50-1400ml
1:E:1:0.2-1:9.9,adjustable
Maximum airway pressure:6kpa
● Respiratory monitor:
Tidal volume:50-1500ml
MV: 6-40L/min
Oxygen concentration:21-100%
Airway Pressure:0-9.9kpa
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634