AD-GL9
ARCHMED
CSI(cerebral state index), BS(Burst surppression) , EMG(electromygrophic signal)and vital signs parameters of patient can be monitored.
CSM is the unique device to monitor people’s level of consciousness according to the score standard of MMOAS
15’’ color, high brightness, wide view angle TFT LCD scree
Streamlined and fashionable design, foldable hook handle, easy to carry.
Remote control and knob operation, friendly man-machine dialogue interface, easier to operation.
Clear depth of anesthesia monitoring interface, the CSI displayed all the time, real-time monitor patient‘s depth of anesthesia
Applicable to adults, children, neonate monitoring.
EEG sensitivity:±400µV
Noise: < 2µVp-p, < 0.4µV RMS, 1–250 Hz
CMR: >140dB
Input impedance: >50MOhm
Sample rate: 2000 samples/sec.: (14 bits equivalent)
CSI and update: 0-100. Filter 6-42 Hz, 1 sec. update
EMG: 0-100 logarithmic. Filter 75-85 Hz, 1 sec. update
BS%: 0-100%. Filter 2-42 Hz, 1 sec. update
Alarms: High / Low with user selectable limit
Artefact rejection: Automatic
Sensor impedance range: 0-10kOhm / measurement current 0,01µA
Memory: Data recording 18 hours
Input; 3 wires/5wires ECG cable
Lead section; I、II、III、aVR、aVL、aVF、V
Gain selection; ×1/4 、×1/2、×1、×2、×4 and automatic
Sweep speed: 6.25 mm/s 、12.5 mm/s 、25 mm/s、50mm/sHeart rate range: 15-300 BPM, Heart calibration: ±1 mvHeart rate accuracy: ± 1 %
Philosophy: Osillometric method
Measurement type : adult, pediatric, neonatal
Measurement parameters:: Systolic, Diastolic, Mean
Measurement method: manual, automatic, continuous measurement
Unit: mmHg/kPa selectable
Accuracy: ±2 or ±3mmHg
GMI SpO2
Display type: Waveform, data
Measurement range: 0~100%
Resolution: 1 BPM
Pulse rate range: 30~250bpm
Accuracy: ±1bpm
Number of channel: 2 channels, surface and rectal temperature can be monitored simultaneouslyAccuracy: ± 0.1 ℃
Display: T1、T2、△T
Thoracic impedance & nasal tube double method selectableMeasurement range: 0-120bpmAccuracy: ± 1 BPM Resolution: 1 BPM
Measurement method: main/side streamMeasurement range: 0%-10.0%Accuracy:± 2mmHg
Power requirements Input: 100~240 V AC, 50/60Hz
Standard configuration | CSI, BS, EMG, SQI, ECG, Suntech NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. |
Optional configuration | Built-in printer, Touch screen, Wall Mount, Moving cart, Nellcor SpO2. |
CSI(cerebral state index), BS(Burst surppression) , EMG(electromygrophic signal)and vital signs parameters of patient can be monitored.
CSM is the unique device to monitor people’s level of consciousness according to the score standard of MMOAS
15’’ color, high brightness, wide view angle TFT LCD scree
Streamlined and fashionable design, foldable hook handle, easy to carry.
Remote control and knob operation, friendly man-machine dialogue interface, easier to operation.
Clear depth of anesthesia monitoring interface, the CSI displayed all the time, real-time monitor patient‘s depth of anesthesia
Applicable to adults, children, neonate monitoring.
EEG sensitivity:±400µV
Noise: < 2µVp-p, < 0.4µV RMS, 1–250 Hz
CMR: >140dB
Input impedance: >50MOhm
Sample rate: 2000 samples/sec.: (14 bits equivalent)
CSI and update: 0-100. Filter 6-42 Hz, 1 sec. update
EMG: 0-100 logarithmic. Filter 75-85 Hz, 1 sec. update
BS%: 0-100%. Filter 2-42 Hz, 1 sec. update
Alarms: High / Low with user selectable limit
Artefact rejection: Automatic
Sensor impedance range: 0-10kOhm / measurement current 0,01µA
Memory: Data recording 18 hours
Input; 3 wires/5wires ECG cable
Lead section; I、II、III、aVR、aVL、aVF、V
Gain selection; ×1/4 、×1/2、×1、×2、×4 and automatic
Sweep speed: 6.25 mm/s 、12.5 mm/s 、25 mm/s、50mm/sHeart rate range: 15-300 BPM, Heart calibration: ±1 mvHeart rate accuracy: ± 1 %
Philosophy: Osillometric method
Measurement type : adult, pediatric, neonatal
Measurement parameters:: Systolic, Diastolic, Mean
Measurement method: manual, automatic, continuous measurement
Unit: mmHg/kPa selectable
Accuracy: ±2 or ±3mmHg
GMI SpO2
Display type: Waveform, data
Measurement range: 0~100%
Resolution: 1 BPM
Pulse rate range: 30~250bpm
Accuracy: ±1bpm
Number of channel: 2 channels, surface and rectal temperature can be monitored simultaneouslyAccuracy: ± 0.1 ℃
Display: T1、T2、△T
Thoracic impedance & nasal tube double method selectableMeasurement range: 0-120bpmAccuracy: ± 1 BPM Resolution: 1 BPM
Measurement method: main/side streamMeasurement range: 0%-10.0%Accuracy:± 2mmHg
Power requirements Input: 100~240 V AC, 50/60Hz
Standard configuration | CSI, BS, EMG, SQI, ECG, Suntech NIBP, SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery. |
Optional configuration | Built-in printer, Touch screen, Wall Mount, Moving cart, Nellcor SpO2. |
ROOM.106, BUILDING 10, NO.155, SHANGYUAN STREET, JIANGNING DISTRICT, NANJING, CHINA
Mr Aaron Dong; Ms Alice
+86-025-58095296
+86-13675117634