AD-GC3 Patient Monitor
Home » Products » Surgery & Life Support » Patient Monitor » AD-GC3 Patient Monitor

Product Category

loading

Share to:
sharethis sharing button

AD-GC3 Patient Monitor

Multi-parameter patient monitor
Availability:
Quantity:
  • AD-GC3

  • ARCHMED

The new model, 6 parameters of the 7 wave, 10.4 " color TFT-LCD display screen. Selection of NELLCOR oxygen plate or a digital oxygen plate. Resistance to weak pulse, anti motion interference, brightness adjustable volume unique. High-energy rechargeable battery.
1.Super ability in against electrosurgical interference. Neither in cutting nor in burning, ECG waveform and HR can be influenced, very short recovering time after defibrillation, especially suitable for use in emergency or operating room.
2.Unique thoracic impedance & nasal tube double model respiration test method (when patient can not lie quietly, only nasal tube respiration can detect the right respiration waveform and respiration rate).
3.10.4 color TFT LCD screen, High brightness,Wide viewing, 7 waveforms can be displayed on the same screen . lightness and volume are adjustable independently.
4.Streamlined outline design with sense of the times & foldable handle.
5. Multi-language interface selection: Chinese, English, Spanish, Portuguese, French, Arabic, Russian, Italian, Turkish, etc.


ECG

Heart rate(HR)

Measurement range: 30BPM ~ 300BPM;

Accuracy: 1 BPM or ±1 %.

Heart rate alarm settings And tolerance: upper limit (60 ~ 300) bpm; tolerance::± 10% Lower limit (10 ~ 200) bpm; tolerance : ± 10%

Noise level: ≤ 30μV

ECG frequency response: filtering methods: (1 ~ 25) HzNon-filtered mode: (0.05 ~ 100) Hz The ECG Input circuit current: ≤ 0.1μAECG sensitivity: continuous adjustable

The scanning speed of the sub-file and error:Scan rate can be divided into three files for selection: 12.5mm / s, 25mm / s, 50mm / sThe error of scanning rate: ≤ ± 10%

 

NIBP

Measurement range:    

Systolic(SBP):(5.3 ~ 36.0)kPa,or(40 ~ 270 )mmHg    

Diastolic (DBP):(2.7 ~ 26.7)kPa,or(20 ~ 200 )mmHg  

Mean (MAP):(4.0 ~ 29.3)kPa,or(30 ~ 220 )mmHg

Accuracy : ≤ ± 0.4 kPa (3 mmHg) or ±2%,

 

IBP

Measurement range: -1.3~40KPa(-10 ~ 300mmHg)

Channel: 2 channelsTransducer sensitivity: 5MV/V/mmHg

Unit display: kPa or mmHg( selectable)

 

Respiration Rate

Measurement range: 0 BPM ~ 120 BPM;

Accuracy: ±1 BPM or ±5 %

 

Temperature

Number of channels: 2

Temperature probe configuration: Intracavitary probe: 1 unit; Surface probe: 1 unit

Measurement range: 25.0 ℃~ 45.0℃

Accuracy: ± 0.2 ℃

Response time: ≤ 3 min.

 

SpO2    

 Display type: Waveform, data    

 Measurement range: 0~100%

 Resolution: 1 BPM

 Pulse rate range: 30~250bpm

Accuracy: ±1bpm

 

Pulse Rate

Measurement range: (30 ~ 250)bpm;

Accuracy: 1BPM or ±2%  

 

Trend review:

Can Review history data of 360 hours

 

CO2:

Measurement range: 0﹪ ~ 10.0﹪ ( Carbon dioxide inhalation and carbon dioxide exhalation)

Accuracy: ±2mmHg(<5﹪ Measured values)

10﹪(>5﹪ Measured values)


 


Standard configurationECG, NIBP,  SpO2, HR/PR, 2-RESP, 2-TEMP, rechargeable battery.
Optional configurationBuilt-in printer, Nellcor SpO2,2-IBP, ETCO2(main stream or side stream), CO, AG,Wireless network, Wall Mount, Moving cart, 12 volts Power supply